Your shopping cart is empty!
The Domus STREAM 6-in-1 is a slimline bathroom heater, fan andlight 2,250W, 240V, 500m/hextraction, 48dB, 595280mm cutout, with adigital wall controller. 2,250 W is 94% of a standard lighting circuit…
The Domus STREAM 6-in-1 is a slimline bathroom heater, fan andlight 2,250W, 240V, 500m/hextraction, 48dB, 595280mm cutout, with adigital wall controller.
3000K gives 1,500lm, 4000K gives 1,850 and 5000K gives1,750. That is enough to be a bathroom’s main light in most cases, which is worthknowing because it changes the rest of the plan if this unit lights the room, the ceiling needsnothing else except perhaps a vanity light. CRI 80 is adequate for a bathroom but notfor close colour work; if someone does makeup in this room, a separate vanity light at higher CRI is worthhaving.
The cutout is 595280mm and the fascia is615315mm so the fascia covers 20mm each way, which isnot a lot of tolerance. A 595mm cutout is longer than the gap between manyceiling joists at 450mm centres so it may need a joist trimmed andnoggins added, which is a framing job rather than an electrical one. CHECK THE JOIST DIRECTION AND SPACING BEFORE ORDERING, not after theceiling is up.
The sheet held against this product could not be confirmed as belonging to it. We have used it only where it agrees with the product’s own record the 2,250Wload and the IPX2 rating appear in both. The airflow, noise, cutout and lumen figurescome from that sheet alone, so treat them as indicative and confirm the cutout with us before you order it is the one figure that cannot be corrected afterwards. No warranty is published for this product at all.
| Specification | Value |
|---|---|
| Load | 2,250W = 9.4A = 94% of a 10A circuit |
| Dedicated circuit | Required and nothing on the listing says so |
| IP rating | IPX2 dripping water only, outside the shower zone |
| Extraction | 500m/h a full air change every ~70sec |
| Noise | 48dB the figure that decides whether it gets used |
| Cutout | 595 280mm may need a joist trimmed |
| Fascia | 615 315mm only 20mm cover each way |
| Duct | 150mm 3m flexible duct and grille included |
| Light output | 1,500 / 1,850 / 1,750lm CRI 80 |
| Sheet status | Unverifiable used only where the record agrees |
| Warranty | Not published |
Slimline bathroom heater, fan and light. 2,250W at 240V. 500m/h extraction,48dB. 150mm duct, 3m flexible duct and exterior grille included. Light 1,500/1,850/1,750lm across three colour temperatures, CRI 80. Digital wall controller. Cutout 595 280mm, fascia615 315mm. IPX2. IT DRAWS 9.4 A 94% OF A STANDARD 10 A LIGHTING CIRCUIT, ON ITS OWN, BEFORE A SINGLE LIGHT ISCONNECTED. It needs a dedicated circuit and nothing on the listing says so; that gets discovered atrough-in when the cable is already run. IPX2 MEANS DRIPPING WATER ONLY, so it belongs in a ceilingposition outside the shower zone normal for a heater, which needs airflow through it, but it means therating decides the position. AND THE 595 mm CUTOUT IS LONGER THAN A 450 mm JOIST GAP check the framingbefore ordering.
Supplied and supported by Lights For You.
Can it go on an existing lighting circuit?
No. 2,250W at 240V is 9.4 amps, and a standard 10A lighting circuit carries 2,400W so this one appliance is 94% of that circuit before a single light is connected to it. It needs a dedicated circuit, and nothing on the listing says so. Tell your electrician before the walls close: adding a circuit at rough-in is routine, adding one afterwards means chasing walls.
Is it drawing that all the time?
No. The load is almost entirely the heating elements the fan motor is 60W and the light a few more. Running the fan and light alone draws almost nothing; it is only when the heat is on that the circuit is loaded.
What does IPX2 mean?
The X means ingress of solids was not tested not that there is no protection, but that no figure is claimed. The 2 means protection against dripping water when the unit is tilted up to 15 degrees. That is the lowest water rating in common use for a bathroom product.
Where can I install it?
A ceiling position outside the shower zone. It is not a fitting for directly above a shower or a bath. That is normal for this class of product rather than a deficiency a heater needs airflow through it, and a fully sealed heater is a contradiction but it does mean the rating decides the position rather than where the heat would be most welcome. Confirm the zone with your electrician against the current wiring rules.
Is 500 cubic metres an hour enough?
Comfortably. A typical bathroom of about 10 cubic metres is a complete air change roughly every 70 seconds, which clears steam quickly enough to stop it reaching the ceiling and the mirror. But the ducting is what delivers it: 150mm, kept short and straight. Every bend costs airflow and adds noise, and a long flexible duct with sags in it can halve the effective extraction.
Why does the noise figure matter?
Because it determines whether the fan gets turned on. An extraction fan people find unpleasant is a fan that runs for two minutes instead of twenty, and mould follows. 48dB is roughly the level of quiet conversation noticeable but not intrusive.
What should I check before ordering?
The ceiling framing. The cutout is 595 x 280mm and the fascia 615 x 315mm, so there is only 20mm of cover each way. A 595mm cutout is longer than the gap between many ceiling joists at 450mm centres, so it may need a joist trimmed and noggins added a framing job rather than an electrical one. Check the joist direction and spacing before ordering, not after the ceiling is up.
Only logged in customers who have purchased this product may leave a review.
We offer fast and reliable shipping worldwide. All orders are carefully packaged and shipped within 1–3 business days after payment confirmation.
Standard shipping, expedited shipping and express delivery options are available at checkout. Delivery time depends on your destination country and local logistics.