Domus SUNSET-Rd-300 25W LED Sensor Oyster / TRIO

$47.995 $95.99
SKU: KO80391096052
Availability: in Stock

The Domus SUNSET-300-RND-SEN is a surface-mounted LED oyster with amicrowave sensor 300mm, 25W,2,5002,650lumens, IP54, IK10, ClassII, switchable 3000/4000/5700K. Identical to the emergency version, minus the emergency Same 25W, same 2,500…

Qty:

The Domus SUNSET-300-RND-SEN is a surface-mounted LED oyster with amicrowave sensor 300mm, 25W,2,5002,650lumens, IP54, IK10, ClassII, switchable 3000/4000/5700K.

Identical to the emergency version, minus the emergency
  • Same 25W, same 2,500 to 2,650lumens, same IP54, same IK10, same Class II, samemicrowave sensor with the same adjustable detection area and standby periods.
  • SO THE CHOICE BETWEEN THEM IS NOT A LIGHTING DECISION AT ALL IT IS A COMPLIANCEONE. Where the building requires emergency lighting at that position, take theemergency version; where it does not, this one does everything else identically.
  • THAT MAKES MIXING THEM STRAIGHTFORWARD AND SENSIBLE. A corridor typicallyneeds emergency luminaires at specified intervals, not at every position so a run can alternatebetween the two versions and look completely uniform, because they are the samefitting.
  • Tell us the emergency spacing your certifier requires and we will split the order betweenthe two versions. Buying every position as an emergency fitting is the simplest orderand usually an expensive one.
The sensor, and what to set it to
  • Microwave rather than PIR: unaffected by ambient temperature, detects through thinmaterials, and more sensitive to small movement. In a corridor that combination isright it will hold on for someone standing still, where a PIR often will not.
  • DETECTION AREA is adjustable at 100%, 75%, 50% and 25%. REDUCE IT IF THE FITTING TRIGGERS FROM AN ADJACENT SPACE microwave passes through plasterboard, so a corridor fitting near an apartment door can seemovement inside the apartment. That is the single most common complaint with microwavesensors and it is a setting, not a fault.
  • STANDBY PERIOD is 0s, 1min or 10min. In a stairwell,10 minutes is usually right people move slowly and a light that drops out mid-flight is worse thanone that runs a little longer. In a store room, 1 minute is enough.
  • A daylight threshold is also published, so the fitting can be stoppedfrom triggering during the day in a corridor with a window.
IK10 in a common area is the specification that survives

IK10 is the highest impact rating in common use a 20joule impact, roughly a5kg mass dropped 400mm. IN AN APARTMENT CORRIDOR, A CAR PARK OR A SCHOOL,FITTINGS ARE HIT BY FURNITURE, LADDERS AND SPORTS EQUIPMENT ROUTINELY. A polycarbonate IK10 body is what stops a common area needing a fitting replaced every fewmonths, and on a strata building the replacement labour costs more than the fitting everytime.

Class II no earth required

Double insulated, so it installs where there is no earth at the fitting. ON A REFIT OF AN OLDER COMMON AREA THAT IS OFTEN THE DECIDING PROPERTY a Class I metal fitting cannot legally go there without rewiring the circuit, and rewiring astrata common area is a project rather than a maintenance job. The polycarbonate body isa deliberate engineering choice, not a cost one.

Dimmable by remote only, and the remote matters

The sheet says dimmable with remote control only. It cannot be dimmed from a wall dimmer, so a scheme assuming a dimmer circuit will notwork. AND ON A COMMON AREA THE REMOTE BECOMES BUILDING EQUIPMENT. Sensor settings, standby period and dim level all live in it, so if it is lost the fittings keeptheir last settings and become unadjustable. Ask us about the remote when you order,and make sure the building manager knows it exists.

TRIO switching across three colour temperatures

3000, 4000 and 5700K, selected at installation. IN A COMMON AREA, 4000K IS USUALLY THE RIGHT ANSWER warm enoughnot to feel institutional, cool enough to read as clean and to give reasonable camera clarity if there isCCTV. Set every fitting in a corridor to the same temperature and record it, because a replacement fitting years later defaulting to a different setting is exactly how auniform run stops being uniform.

What is published
Specification Value
vs the emergency version Identical but for the emergency function
So the choice is A compliance decision, not a lighting one
Output / load 2,500 / 2,650 / 2,600lm 25W
Sensor Microwave area 100/75/50/25%, standby 0s / 1 / 10min
Through-wall triggering Reduce the detection area a setting, not a fault
Impact / class IK10 Class II, no earth required
IP / beam / CRI IP54 120 CRI 80
Colour temperatures 3000 / 4000 / 5700K 4000K usually right in a common area
Dimming Remote only and the remote holds the settings
Warranty Not published
Where it works
  • Common-area positions not requiring emergency mix with the EM version.
  • Car parks and school corridors IK10.
  • Older common areas with no earth Class II.
  • Corridors where people stand still microwave holds on.
  • Not on a wall dimmer.
Specifying it

Surface-mounted LED oyster with microwave sensor, 300mm. 25W, 2,5002,650lm,3000/4000/5700K switchable. CRI 80, 120 beam. IP54, IK10, Class II. Detection area 100/75/50/25%,standby 0s / 1min / 10min. Dimmable by remote control only. 50,000hrs. IT IS IDENTICAL TO THE EMERGENCY VERSION BUT FOR THE EMERGENCY FUNCTION same output, sameIP54, IK10 and Class II, same sensor and settings. SO THE CHOICE BETWEEN THEM IS A COMPLIANCE DECISIONRATHER THAN A LIGHTING ONE, which makes mixing them straightforward: a corridor needs emergency luminairesat specified intervals, not at every position, so a run can alternate between the two versions and lookcompletely uniform. Buying every position as an emergency fitting is the simplest order and usually anexpensive one.

Supplied and supported by Lights For You.

Questions

How does it differ from the emergency version?

Only in the emergency function. Same 25W, same 2,500 to 2,650 lumens, same IP54, IK10 and Class II, same microwave sensor with the same adjustable detection area and standby periods. So the choice between them is not a lighting decision at all it is a compliance one.

Can I mix the two versions?

Yes, and it is usually the sensible order. A corridor typically needs emergency luminaires at specified intervals rather than at every position, so a run can alternate between the two and look completely uniform, because they are the same fitting. Tell us the emergency spacing your certifier requires and we will split the order. Buying every position as an emergency fitting is the simplest order and usually an expensive one.

Why does it trigger when nobody is in the corridor?

Almost certainly through-wall detection. Microwave passes through plasterboard, so a corridor fitting near an apartment door can see movement inside the apartment. Reduce the detection area it is adjustable at 100%, 75%, 50% and 25%. That is the single most common complaint with microwave sensors and it is a setting, not a fault.

What standby period should I use?

In a stairwell, 10 minutes is usually right people move slowly and a light that drops out mid-flight is worse than one that runs a little longer. In a store room, 1 minute is enough. A daylight threshold is also published, so the fitting can be stopped from triggering during the day in a corridor with a window.

Is IK10 worth paying for?

In a common area, yes. It is the highest impact rating in common use roughly a 5kg mass dropped 400mm and in an apartment corridor, car park or school, fittings are hit by furniture, ladders and sports equipment routinely. A polycarbonate IK10 body is what stops a common area needing a fitting replaced every few months, and on a strata building the replacement labour costs more than the fitting every time.

What does Class II give me?

It installs where there is no earth at the fitting. On a refit of an older common area that is often the deciding property a Class I metal fitting cannot legally go there without rewiring the circuit, and rewiring a strata common area is a project rather than a maintenance job.

Why does the remote matter so much?

Because it holds the settings. Sensor detection area, standby period and dim level all live in it, so if it is lost the fittings keep their last settings and become unadjustable. It also cannot be dimmed from a wall dimmer at all. Ask us about the remote when you order, and make sure the building manager knows it exists.

Only logged in customers who have purchased this product may leave a review.

Shipping policy for our store

We offer fast and reliable shipping worldwide. All orders are carefully packaged and shipped within 1–3 business days after payment confirmation.

  • Fast shipping within 1-3 business days
  • Free shipping on orders over $40
  • 30 days money back guarantee
  • 24/7 online customer support
  • Secure packaging & safe delivery

Standard shipping, expedited shipping and express delivery options are available at checkout. Delivery time depends on your destination country and local logistics.