The Domus THOR-PRO-23 is a recessed adjustable LED downlight 23W, CRI 90, 36 beam standard,100mm cutout, switchable 3000/4000/5000K, inwhite or black.
| Colour temperature | White | Black | Difference |
|---|---|---|---|
| 3000K | 2,000lm | 1,700lm | 15.0% |
| 4000K | 2,100lm | 1,800lm | 14.3% |
| 5000K | 2,000lm | 1,750lm | 12.5% |
| Model | Mean black penalty |
|---|---|
| THOR-PRO 23W this | 13.9% |
| THOR-PRO 15W | 1.4% |
| SLENDA 250 / 300 / 400mm | 2.6% / 0.2% / 6.7% |
The same 23W head is available recessed (this), surfacemounted and as a 3-circuit track head with the same62mm diameter cover and 170mm housing throughout. THAT IS MORE USEFUL THAN IT SOUNDS ON A FITOUT. A shop with a plasterboardceiling in one area, a concrete soffit in another and track over the display run can use one light sourcethroughout, so the beam, the colour and the rendering are identical everywhere. Mixing three different fittings to solve three mounting problems is the common alternative and itshows.
Fully dimmable with a suitable dimmer. The family description alsoemphasises stable, flicker-free operation which in a retail setting mattersbeyond comfort, because flicker is what makes phone and camera footage of a shop lookpoor. Anywhere customers photograph the product or the space, it is worthspecifying. Confirm the dimmer type with us before ordering; a mismatched dimmer is theusual cause of flicker on an otherwise sound fitting.
50,000 hours at commercial duty of 12 hours a day is roughly eleven years. No warranty is published on this listing. On a commercial fitout the warrantyterm and whether it distinguishes residential from commercial duty is worth having in writing beforeordering several Domus ranges make that distinction and this listing does notsay. Ask us.
| Specification | Value |
|---|---|
| Output, white | 2,000 / 2,100 / 2,000lm |
| Output, black | 1,700 / 1,800 / 1,750lm 13.9% lower |
| Read per model | The 15W in the same housing differs by only 1.4% |
| Load / CRI | 23W CRI 90 |
| Beam angles | 15 24 36 45 60 (36 standard) |
| Cutout | 100mm |
| Same head, three mountings | Recessed surface 3-circuit track |
| Housing | 62mm cover 170mm CNC aluminium |
| Dimmable | Yes flicker-free, which matters on camera |
| Warranty | Not published ask before a commercial order |
Recessed adjustable LED downlight. 23W at 240V AC. White 2,000/2,100/2,000lm;black 1,700/1,800/1,750lm. 3000/4000/5000K switchable. CRI 90. Beam 15, 24, 36, 45 or 60(36 standard). 100mm cutout. 62mm cover, 170mm CNC aluminium housing. Dimmable,flicker-free. IP20. 50,000hrs. THE BLACK FINISH COSTS 13.9% OF THE LIGHT HERE the largest gap measured in this programme,and on a scheme designed to a lux target that is roughly one fitting in seven. BUT IT IS NOT A RULE: the15 W model shares the same 62 mm housing and differs by only 1.4%, which rules out geometry as theexplanation just as the SLENDA range ruled out reflectance. Across five models in two families the gap runs0.2% to 13.9%, so it must be read PER MODEL. On this one, design to the black figures if you specifyblack.
Supplied and supported by Lights For You.
How much light does the black version lose?
About 14% 15.0% at 3000K, 14.3% at 4000K and 12.5% at 5000K. That is the largest black/white gap measured anywhere in this catalogue, and on a scheme designed to a lux target it is roughly one fitting in seven. Budget for it or specify white.
Does that apply to other black fittings?
No, and this family proves it. The THOR-PRO 15W shares the same 62mm housing and differs by only 1.4%. Across five models in two unrelated families the gap runs from 0.2% to 13.9%.
What causes it then?
We are not offering a mechanism. The 15W and 23W sharing a housing and differing by 12.5 points rules out fitting geometry, just as the three SLENDA sizes ruled out simple reflectance. What we can say is that the published figures are real and must be read per model on this one, design to the black figures if you specify black.
Why choose CRI 90 over a standard downlight?
Because in a shop, colour rendering is what makes stock look like itself. Fabric, food, timber and skin all read wrong under CRI 80. At 23W with CRI 90 this is a genuine retail specification rather than a general-purpose fitting.
What do the five beam angles do?
15 degrees is a spot for a single object, a plinth or a piece of art and unforgiving if the aim is slightly off. 24 to 36 is display lighting for a shelf bay, a table or a counter run. 45 to 60 is general lighting for circulation or an office. From a 3m ceiling to a 1m display surface, a 36 degree beam lights a circle about 1.3m across and a 60 degree beam about 2.3m. Choose the angle from the object, not the room.
Why does one head in three mountings matter?
On a fitout with mixed ceilings, a great deal. A shop with plasterboard in one area, a concrete soffit in another and track over the display run can use one light source throughout, so the beam, the colour and the rendering are identical everywhere. Mixing three different fittings to solve three mounting problems is the common alternative and it shows.
Is flicker-free operation worth specifying?
In retail, yes beyond comfort. Flicker is what makes phone and camera footage of a shop look poor, so anywhere customers photograph the product or the space it matters. Confirm the dimmer type with us before ordering: a mismatched dimmer is the usual cause of flicker on an otherwise sound fitting.