The Luta is an adjustable recessed inground uplighter with a316 stainless steel cover on an aluminium body, and this listing sells theround part, HV1825T. It drops into a canister set below ground leveland finishes flush behind a clear glass face. Havit rates it trafficable to 500 kg foot traffic and a light domestic vehicle, and materially less than the 1000 kgof Havits Klip and Toldo inground ranges, so check the load before you put it under adriveway a heavy vehicle will use.
Unlike most of Havits inground range, the Luta is not a built-in LED fitting. Ithas an MR16 lamp base and ships with a 5 W tri-colour MR16 globefitted. That globe produces 270 lm at 3000K,285 lm at 4000K and 300 lm at5500K through a 120 beam at CRI >80 so thosefigures describe the light as it is supplied, and the beam angle is set by whicheverglobe is in it, not by the fitting. Havits ceiling is 20 W MR16, and thefittings own lamp expectancy is >30,000hrs.
The tri-colour selector is on the side of the globe, not on the fitting. Havitsstep 10 has you unscrew the 4 nuts, remove a C-clip and ease theglobe out to reach it. It leaves the factory on 3000K, so set the colourtemperature before it goes into the ground. The head tilts up to 30, so youcan aim it at a wall or a tree.
This is a 12 V DC constant-voltage fitting, so it runs from a suitable12 V DC LED driver. It must not be connecteddirectly to 240 V. It is Protection Class III low voltage, no earthingrequired, which all three of Havits current documents state the same way. Fittingsare wired in parallel, and the supply reaching each one has to stay within5% of the rated voltage or the warranty is void volt drop on along garden run is the usual reason that limit is missed.
Havits drawing gives the cutout with the canister as 104 mm. Drainage below the canister is a warranty condition, not a suggestion: Havit asks fora 100 mm space beneath the canister and 100150 mm of crushed rockbelow that, and states plainly that where no drainage is allowed the warranty will bevoided. The canister must finish level with the ground failure to do sovoids the warranty in its own right. Theanti-syphon plug and the male and female connector on the300 mm tail must both stay on the cable; every o-ring and seal has tobe seated, joins soldered and covered watertight, and silicone run around the edge.It is IP67 and IK10. 316 stainless still needsregular cleaning to stop tea staining forming, and tea staining is not coveredby the warranty Havits HV9971 kit is made for that job. HavitsHV9507 and HV9508 tri-colour MR16 globes are the listed replacements.At Lights For You we built this page from Havits currentHV1825T data sheet and its FEB24 installation instructions, whichstate a 3 Years Replacement Warranty.
Can I drive over it?
Only lightly. Havit rates the Luta at 500 kg trafficable, with an IK10 impact rating. That is half the 1000 kg of Havits Klip and Toldo inground fittings, so for a driveway carrying a heavy vehicle choose one of those instead. The canister also has to be set level with the finished surface, which Havit makes a warranty condition on its own.
Does it come with a globe, and can I change it?
Yes to both. It ships with a 5 W tri-colour MR16 globe fitted, and the base is a standard MR16, so the globe is replaceable up to Havits ceiling of 20 W MR16. Because the globe produces the light, the lumen figures and the 120 beam on this page describe the supplied globe fit a different one and both change.
How do I set the colour temperature?
The switch is on the side of the globe, not on the fitting. Unscrew the 4 nuts on the back, remove the C-clip, ease the globe out by its outer rim, move the switch to 3000K, 4000K or 5500K, then refit the globe and the C-clip and retighten the nuts with the seals in place. Do this before the fitting goes into the ground it leaves the factory on 3000K.
Can it be dimmed?
Not with the globe it comes with. Havit records the Luta as not dimmable with the supplied globe which is a statement about that globe, not about the fitting, because the MR16 base is replaceable. If you need a dimmed circuit, tell us the driver and dimmer you intend to use and we will check the combination with you before you buy rather than guess.
How big does the hole need to be?
Havits drawing gives the cutout with the canister as 104 mm. The same drawing carries two further figures under a single without canister label with nothing saying which is the hole and which is the face, so we have not published those open the dimension drawing in the Data Sheet & Manual panel before you cut.
Does it need a driver?
Yes a 12 V DC LED driver. It must not be connected directly to 240 V. Fittings run in parallel, and the voltage arriving at each one has to stay within 5% of rated or the warranty is void, so size the driver and the cable for the whole run rather than for one light.
What has to be done for the warranty to stand?
Four things Havit names explicitly: adequate drainage beneath the canister, the canister set level with the ground, all connections soldered and sealed watertight, and every o-ring and seal in place. The anti-syphon plug and the male and female connector must stay fitted, and tea staining on the 316 stainless is not covered, so clean it regularly.