Your shopping cart is empty!
The Domus Maxi 50 is a 1.7m suspended LED linear pendant 34W, 3400lm, 4000K atCRI90, dimmable, in a white body, in six finishes.
Domus asks you to call and confirm it and on a retrofit the oldfitting comes down before the new one arrives. Settle it first.
| Twin 58W fluorescent batten | This fitting | |
|---|---|---|
| Input power | 130W with gear | 34W |
| Efficacy | 77lm/W at the lamp | 100lm/W |
| Colour rendering | Typically CRI8085 | CRI90 |
| Where the light goes | Sideways and upward as well as down | All downward at 120 |
| Maintenance | Tubes replaced periodically | No lamp the fitting is replaced |
| Specification | Value |
|---|---|
| Light output | 3400lm 100lm/W |
| Colour rendering | CRI90 at 4000K |
| Power / length | 34W at 240V 1700mm |
| Beam | 120, down only |
| IP rating | IP20 many batten positions are damp or dusty; check |
| Suspension | 3m drop supplied |
| Dimming | DALI and emergency on request |
| Warranty | 3 years, replacement |
| Lifespan spacing weight | Not published |
It is close to what a standard fluorescent tube delivered, so the room doesnot change character. 3000K in a space people are used to seeing under cool whitereads as dim even when it is not the eye judges brightness partly by colourtemperature. It is also the more efficient option: 3400lm against3060lm.
1.7m suspended LED linear pendant. 3400lm, 34W (100lm/W), 4000K,CRI90. IP20. 1700mm. 3m drop. PLEX-COB-20W strip, integral dimmable driver, DALI and emergencyon request. White powder-coated aluminium body. Six finishes. 3-year replacement warranty. Order codeMAXI-50-1.7M-W-4K. AGAINST A TWIN 58W FLUORESCENT BATTEN: about 130W down to 34W, 77lm/W upto 100, and CRI8085 up to CRI90. The raw lumen figures look unfavourable and are misleading a barelamp is measured AT THE LAMP, and an open batten throws much of that sideways and upward, where thisfitting directs all 3400lm downward. Compare the working plane, not the datasheet.
Supplied and supported by Lights For You.
Can this replace a fluorescent batten?
It is a sensible replacement for a 5ft twin, and the comparison can now be made properly. Input power drops from about 130W with gear to 34W. Efficacy rises from roughly 77 lumens per watt at the lamp to 100. Colour rendering improves from a typical CRI80 to 85 up to CRI90. And the flicker and warm-up of a fluorescent tube go away.
But the batten produces more lumens is this a downgrade?
The raw comparison is misleading. A bare fluorescent lamp’s output is measured at the lamp, and an open batten throws a large share of it sideways and upward where it does little work. This fitting’s 3400 lumens is directed downward at 120 degrees, so far more of it reaches the working plane. Compare the working plane rather than the datasheet though we would not claim a one-for-one swap without checking your space. Tell us the mounting height and the existing fitting.
What changes physically?
Three things. It is suspended rather than surface-mounted, so it hangs below the ceiling where a batten sat against it 3m of drop is supplied and shortened on site. The fixing is different: suspension points into structure rather than screws into the lining, and the spacing and weight are not published. And there is no lamp, so when it fails the fitting is replaced.
Why 4000K for a retrofit?
Because it is close to what a standard fluorescent tube delivered, so the room does not change character. 3000K in a space people are used to seeing under cool white reads as dim even when it is not the eye judges brightness partly by colour temperature. It is also the more efficient option here at 3400 lumens against 3060 for the same 34W.
What should I tell the maintenance team?
That there is no tube to change. The old batten had lamps replaced periodically; this has none, so a failure means a new fitting. The 3-year replacement warranty is the right form of cover for that, and the rated lifespan is not published worth asking us for if you are building a maintenance schedule around it.
Will the colour rendering improvement be noticeable?
Yes, and it is one of the clearer wins. CRI90 against a typical fluorescent CRI80 to 85 means materials, print and finishes read more accurately reds in particular, which is where lower-CRI sources fall down most visibly. In a workroom or anywhere anything is inspected, that is a real improvement rather than a specification detail.
Can I use it in a damp space?
No IP20, dry interior only, and many batten positions are damp or dusty. That is worth checking before a like-for-like swap rather than after. For those positions, ask us about the Domus IMPACT range at IP66 and IK10.
Only logged in customers who have purchased this product may leave a review.
We offer fast and reliable shipping worldwide. All orders are carefully packaged and shipped within 1–3 business days after payment confirmation.
Standard shipping, expedited shipping and express delivery options are available at checkout. Delivery time depends on your destination country and local logistics.