Your shopping cart is empty!
The Domus MURO-PRO-15 is a single-head exterior spotlight 15W, 9501,050lumens, IP54,120 beam, switchable 3000/4000/5000K, in black,dark grey or white. All three sources agree here and that is what exposed its…
The Domus MURO-PRO-15 is a single-head exterior spotlight 15W, 9501,050lumens, IP54,120 beam, switchable 3000/4000/5000K, in black,dark grey or white.
The sheet names Bridgelux as the LED, which is unusual most fittingsin this catalogue say only SMD. A NAMED CHIP MANUFACTURER IS A MILDQUALITY SIGNAL: it means the maker is willing to be held to a known part rather than whatever wascheapest that quarter. Lifespan is 30,000hrs rather than the50,000 most fittings here claim. That is not a defect a spotlight runs hotter ina sealed die-cast body than a downlight does, and a realistic figure is more useful than an optimisticone. At four hours a night it is about twenty years.
The sheet says dimmable = No. Do not put it on a dimmercircuit a non-dimmable driver on a dimmer will flicker, buzz or fail. On an exterior spotlight that is rarely a loss; it is a security and utility fitting rather thana mood one. If you want it to come on automatically, the MURO-PRO-15S adds a PIR sensor at IP44 rather than IP54, so check the site before choosingit.
| Specification | Value |
|---|---|
| IP rating | IP54 spec table, prose and record all agree |
| Which exposed | The sensor version’s unaltered spec table |
| vs the 15S | This one is dust-protected; the sensor version is not |
| IP54 does not cover | Jets, hosing, sustained driving rain shelter it |
| Output | 950 / 1,050 / 1,000lm 4000K is the brightest |
| Beam | 120 a FLOOD, not a spot |
| LED | Bridgelux named most here say only “SMD” |
| Construction | Die-cast aluminium + glass glass does not yellow |
| Life / dimmable | 30,000hrs realistic for a sealed body not dimmable |
| Sensor version | MURO-PRO-15S IP44, check the site |
Single-head exterior LED spotlight. 15W at 240V 50Hz.950/1,050/1,000lm at 3000/4000/5000K switchable. CRI 80, 120 beam. IP54. Die-cast aluminiumwith glass cover, Bridgelux LEDs. Not dimmable. 30,000hrs. ALL THREE SOURCES AGREE HERE AT IP54 spec table, prose and record AND THAT IS WHAT EXPOSEDITS SIBLING. The sensor version, the MURO-PRO-15S, has a spec table saying IP54 while its own prose and itsrecord both say IP44; having a clean sibling in the same family is what makes that identifiable as anunaltered spec table rather than an oddity. SO THE DIFFERENCE BETWEEN THE TWO IS NOT ONLY THE SENSOR:this one is dust-protected and the sensor version is not, which on a rural, exposed or dusty site is anargument for the plain fitting plus a separate sensor.
Supplied and supported by Lights For You.
Is its IP rating reliable?
Yes its spec table, its sheet prose and its record all say IP54. That matters beyond this product, because the sensor version has a spec table saying IP54 while its own prose and record both say IP44. Having a clean sibling in the same family is what makes that identifiable as an unaltered spec table rather than an oddity.
So how does it differ from the sensor version?
Not only by the sensor. This one is dust-protected at IP54 and the sensor version is IP44, which is not. On a rural, exposed or dusty site that is an argument for the plain fitting plus a separate sensor rather than the integrated version.
What does IP54 not cover?
Jets, hosing and sustained driving rain IPX4 is splashing water from any direction. So it is a sheltered-position fitting: under an eave, on a wall that is not the weather side, or somewhere a roof or overhang breaks the rain.
Is it a spotlight or a floodlight?
A flood, whatever the name says. A 120 degree beam covers a wide area at low intensity rather than picking an object out of the dark, so it suits a driveway, a yard, a side path or a working area. For uplighting a tree, grazing a wall or highlighting a feature you want 15 to 24 degrees, which this fitting does not offer.
Which colour setting is brightest?
4000K, at 1,050lm against 1,000 at 5000K and 950 at 3000K. The cooler setting is not the brighter one here, which is unusual and worth knowing if you are choosing on output. Outdoors 3000K is still usually the right choice it flatters brick, render, timber and planting where 5000K reads as institutional, and the 100-lumen difference is not visible.
Why only 30,000 hours?
It is a realistic figure rather than a defect. A spotlight runs hotter in a sealed die-cast body than a downlight does, and most fittings here claim 50,000. At four hours a night, 30,000 hours is about twenty years. The sheet also names Bridgelux as the LED, which is unusual most fittings in this catalogue say only “SMD” and a named chip manufacturer is a mild quality signal.
What maintenance does it need?
Clean the glass and check the glass-to-casting seal while you are there. A filmed lens costs more output than people expect, and the seal is the point where an exposed fitting eventually lets water in. Glass has one advantage over acrylic here: it does not yellow, so the output stays where it started.
Only logged in customers who have purchased this product may leave a review.
We offer fast and reliable shipping worldwide. All orders are carefully packaged and shipped within 1–3 business days after payment confirmation.
Standard shipping, expedited shipping and express delivery options are available at checkout. Delivery time depends on your destination country and local logistics.