Your shopping cart is empty!
The Split is a 5 W recessed inground uplighter in 316 stainless steel, and thislisting sells the 12 V DC part, HV1842T. It drops into a canister setbelow ground level, finishes flush with the surface behind a clear tempered-glass face and an anti-glarehoneycomb louvre, and it is trafficable to 1000 kg so it can sit in a path or adriveway and be driven over.
This part runs on 12 V DC constant voltage and an external supply is required: it hasto be run from a suitable 12 V DC constant-voltage LED driver. It isProtection Class III, so no earth is required at the fitting. It must not be connected directly to 240 V. It is alsopolarity sensitive Havit’s installation sheet states that a fitting connected thewrong way round will fail and the warranty is void, so match positive to positive before anything issoldered. Supply at the fitting has to stay within 5% of the rated voltage or thewarranty is void as well. Wiring is parallel, and the installation is work for aqualified electrician working to AS/NZS 3000 with the circuit isolated first.
The built-in LED is tri-colour: 3000K, 4000K and5500K, giving 400 lm, 430 lm and450 lm respectively, through a 60 beam atCRI >80. The selector is a switch on the bottom of the fitting, inside asealed brass cover. On a recessed light that means choose the colour temperature beforeyou drop it into the canister changing it afterwards means lifting the fitting back out andre-sealing the cover. There is no globe and no socket here, so nothing is ever replaced; lamp expectancyis >30,000hrs. The fitting is not dimmable, which both of Havit’sdocuments for this part number state.
It is IP67 and IK10 behind a clear glass diffuser, with a300 mm tail on it. Adequate drainage under the canister is a warrantycondition, not a recommendation Havit asks for 100150 mm of crushed rock and a slight fallon the surrounding ground so water runs away, and says plainly that if no drainage is allowed thewarranty is void. The anti-syphon plug and the male and femaleconnector supplied on the cable must both stay on it for the warranty to be valid. Allo-rings and seals have to be seated, every joint soldered and sealed watertight, andsilicone run around the edge of the fitting once it is in. 316 stainless still needs regular cleaning to stop tea staining forming, andtea staining is not covered by the warranty Havit sells a maintenance kit,HV9971, for exactly that job. A security face with screws is availableseparately as HV1842-F-SH where the fitting is going somewhere public. Lights For Youtook every figure on this page for HV1842T from the HV1842 data sheet (AUG24), thecurrent HV1842T / HV1842RGBW installation instructions and Havit’s own page for thismodel, which states a 3 Years Replacement Warranty.
Can it be wired without a driver?
No. This part is 12 V DC and must not be connected directly to 240 V. It needs a suitable 12 V DC constant-voltage LED driver sized for the run. Havit makes a separate part number of the same fitting for installations that take no driver, and it is a different listing to this one.
Does it matter which way round I connect it?
Yes. It is polarity sensitive. Havit’s installation sheet states that a fitting connected incorrectly will fail and the warranty will be void, so match positive to positive and neutral to neutral before you solder anything.
How do I set the colour temperature?
A switch on the bottom of the fitting, inside a sealed brass cover. Set it to 3000K, 4000K or 5500K and re-seat the cover tightly. Do it before the fitting goes into the canister afterwards the switch is under the light and under the ground.
Can I drive over it?
Yes. Havit rates the Split at 1000 kg trafficable and it is IK10, the top of the impact scale. The canister still has to be set level with the finished surface, which Havit makes a warranty condition in its own right.
What drainage does it need?
100150 mm of crushed rock beneath the canister and a slight fall on the surrounding ground so water runs away from the fitting. Havit is explicit that if no drainage is allowed the warranty is void standing water is the most common way a recessed fitting fails.
Can it be dimmed?
No. Both of Havit’s documents record this part number as not dimmable, so plan a switched circuit rather than a dimmed one. The RGBW version of the Split is the one with variable output, and it is run from an RGBW controller rather than a dimmer.
Does the 316 stainless need looking after?
Yes. Havit requires regular cleaning maintenance on all 316 stainless fittings to stop tea staining forming, and states that tea staining is not covered by the warranty. A rinse and a wipe when you clean the path is usually enough; Havit’s HV9971 kit is the heavier option.
Only logged in customers who have purchased this product may leave a review.
We offer fast and reliable shipping worldwide. All orders are carefully packaged and shipped within 1–3 business days after payment confirmation.
Standard shipping, expedited shipping and express delivery options are available at checkout. Delivery time depends on your destination country and local logistics.